From radiology rooms to MRI centres, ultrasound and hybrid operating theatres:

From radiology rooms to MRI centres, ultrasound and hybrid operating theatres:

Sound is often a challenge.

Imagine walking into a large cathedral. All the hard surfaces in the room make sound bounce back and forth, and you notice that there is noise everywhere, without being able to make out exactly what is being said a few metres away. In many cases, this is exactly what it is like in a hospital operating theatre. 

Radiology rooms, MRI centres, ultrasound rooms, hybrid operating theatres and so on often present acoustic challenges. These spaces need to be safe for the surrounding facilities, so they are often built from concrete, lead and metal: in other words, they have only hard surfaces, like a cathedral. One emerging trend is prefabrication, in which a specialist company produces an off-site construction module with a carefully designed structure that fits into the hospital like a LEGO brick. Unfortunately, these modules and diagnostic facilities are often built without considering the acoustic environment. The hard surfaces do not support communication, and staff face challenges in terms of both work performance and wellbeing.

A success story: acoustic comfort and high hygiene standards at Sundsvall Regional Hospital

Sundsvall Regional Hospital in Sweden was in need of an upgrade. The building had fallen into disrepair and no longer met current standards for accessibility, hygiene and the working environment. In addition, many of its systems had reached the end of their technical service life. A preliminary study was carried out, providing the basis for a new, modern Surgical Centre. It found that, in addition to renovating and extending a number of patient rooms, a new hybrid operating theatre of 105 square metres was needed, with facilities for taking X-rays and ultrasound scans and performing MRI scans. Unfortunately, the planned overall solution for the operating and diagnostic rooms, based on a modular approach, did not meet the room acoustic requirements of the Swedish standard. Floors, walls and ceilings had a negative impact on the acoustic environment, and there was virtually no sound absorption in the prefabricated space. This was due to the properties of the glass and metal used in the module, which increased rather than reduced the reverberation time.

Reverberation time and other room acoustic parameters

Reverberation time tells us how long sounds remain in a room before they fade away. Vowels carry a lot of energy because, when we pronounce them, the sound is not impeded on its way out. By comparison, the energy of consonants is limited by the obstruction of airflow. For example, narrowing the vocal tract creates friction as air passes through it, as when pronouncing the ‘g’ sound.

As reverberation time increases, the sounds with more energy, the vowels, gain the upper hand and speech becomes unclear. The vowels effectively drown out the consonants, even though consonants give speech meaning. When we cannot hear or understand speech, we raise our voices to be heard and sound energy builds up. This is known as the Lombard effect. So, reducing reverberation time from a long value (e.g. 2 sec.) to a short one (0.6 sec.) makes speech easier to understand. 

Overall, sound pressure levels generally fall when sound-absorbing materials are used, creating a calmer acoustic environment. This not only makes the transfer of information more effective and efficient, but also improves acoustic comfort for staff and patients.

Reverberation time under the Swedish standard (SS25268)

Under the Swedish standard (SS25268), reverberation time in an operating theatre must not exceed 0.6 seconds. However, calculations for the hybrid operating theatre showed values of more than 2 seconds. Think again of the effect in a cathedral, and now imagine having to communicate clearly around critically ill patients while your colleagues’ voices compete with the sounds of technical equipment. In these types of clinical areas, there are many sound sources, and peak levels can rise above 100 dB.

In the Swedish case, the project team decided to replace the metal ceiling with an acoustic ceiling, consisting of sound-absorbing panels that meet Class A absorption requirements under ISO 354 and ISO 11654. The chosen ceiling also met hygiene requirements for cleaning and disinfection. Acoustic measurements were carried out in accordance with ISO 3382, and after the ceiling was replaced, the facilities met the acoustic requirements. This means that reverberation time was halved!

What needs to be considered to achieve acoustic comfort?

Diagnostic rooms are crucial for making the right decisions. In addition, the patients involved are too seriously ill and too far outside their comfort zone to be aware of what was said, when, and by whom. The facilities in these areas need to support clear communication to reduce the risk of errors, while also supporting the wellbeing of both staff and patients.

We all deal with sound, but in critical care, noise is still too often seen as a necessary evil. Room acoustics must be part of a sustainable solution for healthcare in general, and creating a ‘cathedral’ in acoustic terms is never the way forward.

The first step towards making such a space acoustically successful is to keep the overall sound level as low as possible, ensure that reverberation time is not too high, and prevent the aforementioned Lombard effect from setting in. This can be achieved by installing a Class A sound-absorbing ceiling that covers the entire ceiling area. To further support the transfer of information, by improving the acoustic parameter known as speech intelligibility, wall panels can be fitted to adjoining walls at right angles to each other. This can effectively reduce grazing waves that bounce back and forth parallel to the floor and ceiling. A brief explanation of these grazing sound waves: when sound hits a sound-absorbing ceiling, not 100% of it is absorbed at once. Some is reflected and can then continue bouncing back and forth lower down in the room between two opposite walls. It effectively becomes ‘trapped’ because the energy has nowhere else to go. With all these acoustic solutions, it is important to remember that they must meet both acoustic and hygiene requirements.

All in all, we need to bear in mind that acoustics are an important factor in activities taking place in hospital rooms dedicated to diagnosis. Good acoustics must therefore not be overlooked in the design if these spaces are to be successful.

ISO 3382-1 defines reverberation time as the time required for the sound pressure level in a room to decrease by 60 dB after the source is switched off. For practical reasons, reverberation time is usually measured over a 20 or 30 dB decay (T20 and T30), starting 5 dB below the initial level, and then extrapolated to the full 60 dB range. Even small changes in reverberation time affect staff: the just noticeable difference (JND) under ISO 3382-1 is only 5%.

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeSafe and reliable healthcare buildings
  • SubjectHospitals
Share this article

Advertisement

Follow on Bouwen aan de Zorg

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.