Healthcare technology

Modular room pressure monitoring system

Modular room pressure monitoring system

The CPS60xx room pressure monitoring system has been specially developed to monitor four rooms simultaneously in settings including hospitals, pharmacies, laboratories and cleanrooms.

The monitoring system comprises 3.2-inch colour LCD touchscreens and differential pressure transmitters, with the touchscreens configured as master or slave units. The differential pressure transmitters are connected to the master touchscreen via an internal RS485 bus. Room pressure status, alarms and readings are also available via Modbus RTU.

The touchscreen turns green when conditions are safe and red when they are unsafe, displaying the word ‘alarm’ and emitting an adjustable audible signal. Room pressure alarm levels and delay times can be freely set and are password-protected.

The standard room pressure monitoring systems (models CPS6020 and CPS6040) can be connected to two and four single-mode differential pressure transmitters, respectively, of type FlowGuard model 6280. The special monitoring systems (models CPS6021 and 6041) can be connected to two and four dual-mode differential pressure transmitters, respectively, of type FlowGuard model 6282 or 6283. The dual-mode FlowGuard model 6282 differential pressure transmitter has four alarms: two for negative room pressure (negative high/low alarm) and two for positive room pressure (positive high/low alarm). The 6282 is designed for convertible patient rooms suitable for source or protective isolation.

The FlowGuard 6283 is the most advanced differential pressure transmitter. In addition to all the functions of the FlowGuard 6282, it measures airflow (l/s), air velocity (m/s) and air changes per hour (ACPH). It has a wide range of applications, including cleanrooms, laboratories and hospitals. Flowguard differential pressure transmitters have an accuracy of ± 0.5 Pa and are optionally available with an auto-zero function, a display or a relay. The measuring range can be freely set from ± 5 Pa, with a 10-bit resolution. The standard analogue U/I output signals can also be freely set. In addition to the analogue output, Flowguard comes as standard with a Modbus output.   

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeFaster, more flexible healthcare construction
  • SubjectHealthcare technology
Share this article

Advertisement

Follow on Bouwen aan de Zorg

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.